Masimo 9992 RD Single-Patient-Use Conversion Kit
$585.20
Quantity
Rapid ShippingQuick Turnaround, Every Time.
Premium StandardISO 13485:2016 Certified Company.
Up to 50% SavingsHigh Quality. Low Cost.
OEM-Standard QualityBacked By Warranty.
Specifications
OEM Part Number Cross References:
| Manufacturer | Part Number |
|---|---|
| Masimo | 9992 |
Compatibility:
| Manufacturer | Model |
|---|---|
| Masimo | Masimo devices that take an RD rainbow SET 20-pin cable (MD20-05 4072, MD20-12 4073) or M20 cable (M20-05 4256, M20-12 4257); MD20 cables are not for use with Rad-8 or Rad-5/5v |
| Masimo | Masimo devices that take an RD rainbow SET 25-pin cable (R25-05 4076, R25-12 4078) or right-angle 25-pin cable (RA25-05 4077) |
| Masimo | Masimo devices that take an RD SET MD14 cable (MD14-05 4080, MD14-12 4081) |
| Masimo | Rad-G devices, with the RD SET G15 cable (G15-05 4773, G15-12 4774) |
| Philips | IntelliVue monitors with Masimo SET or Philips FAST SpO2, with the RD SET MP dual-key cable (MP-05 4082, MP-12 4083) |
| GE | GE monitors that take the RD SET GE patient cable (GE-05 4084, GE-12 4085) |
| Nihon Kohden | Nihon Kohden monitors that take the RD SET NK patient cable (NK-05 4191, NK-12 4192) |
| Spacelabs | Spacelabs monitors that take the RD SET SL patient cable (SL-12 4087) |
Technical Specifications:
| Label | Value |
|---|---|
| Masimo Part Number | 9992 |
| Category | SpO2 Accessories |
| Manufacturer | Masimo |
| Type | RD single-patient-use conversion kit (configured to order) |
| Length | Set by the patient cable selected: 5 ft (-05 cables) or 12 ft (-12 cables) |
| Connector | Depends on the RD SET or RD rainbow SET patient cable selected |
| Contents | 2 boxes of RD SET sensors, 20 per box (Adt 4000, Pdt 4001, Inf 4002 or Neo 4003), and 1 RD SET or RD rainbow SET patient cable, selected when ordering |
| Patient Cable Options (choose 1) | Masimo: 4072 RD rainbow SET MD20-05, 4073 RD rainbow SET MD20-12, 4076 RD rainbow SET R25-05, 4077 RD rainbow SET RA25-05, 4078 RD rainbow SET R25-12, 4080 RD SET MD14-05, 4081 RD SET MD14-12, 4082 RD SET MP-05, 4083 RD SET MP-12, 4084 RD SET GE-05, 4085 RD SET GE-12, 4087 RD SET SL-12, 4191 RD SET NK-05, 4192 RD SET NK-12, 4256 RD rainbow SET M20-05, 4257 RD rainbow SET M20-12, 4773 RD SET G15-05, 4774 RD SET G15-12 |
| Sensor Patient Weight Ranges | Adt 4000: >30 kg; Pdt 4001: 10–50 kg; Inf 4002: 3–20 kg; Neo 4003: <3 kg or >40 kg |
| GTIN | 00843997016001 |
| Latex | Not made with natural rubber latex |
| Condition | New, genuine Masimo, factory packaged |
| Warranty | 6 months |
Product Details
The Masimo 9992 is a genuine Masimo RD Single-Patient-Use Conversion Kit for departments switching from reusable SpO2 sensors to Masimo RD SET single-patient-use sensors. Each kit is built to order: two boxes of RD SET adhesive sensors chosen by patient size (Adt 4000, Pdt 4001, Inf 4002 or Neo 4003) plus one RD SET or RD rainbow SET patient cable chosen to match your monitor.
PM Cables supplies this kit new, genuine Masimo, in its factory packaging. Because the sensors and cable change with every order, send the PM Cables team your monitor model and patient population and we’ll confirm the right configuration before you order.