The Smiths Medical BCI Compatible Short SpO2 Sensor is a new compatible replacement for BCI part 3444. It also interchanges with 12 other OEM part numbers listed in the cross reference table. It fits equipment from Armstrong, Artema SandW, Beijing Choice Electronic and 16 more manufacturers, with 73 supported models in the compatibility list. Certifications include FDA, CE and TUV. Each unit is latex-free and covered by a 12-month warranty.
OEM Part Number Cross References:
| Manufacturer | Part Number |
|---|---|
| AMC | PR-A520-1001N |
| ChoiceMMed | M-50E |
| Envitec | F-3222-12 |
| Huntleigh | ACC-VSM-171 |
| Mediaid | CST060-3104 (3 ft), CST060-31049 (9 ft) |
| Pacific Medical | NFBC100 |
| Sage | P13-11M |
| Smiths Medical > BCI | 3444, 3044, 3044S |
| Tenacore | TCPF-0101-0112, TP1212 |
| Cables and Sensors | S403-060 |
Compatibility:
| Manufacturer | Model |
|---|---|
| Armstrong | AD-1000, AD-2000, AD-3000, AD-4000, AD-900 |
| Artema SandW | Diascope |
| Beijing Choice Electronic | Pulse Oximeter model MD300I1 |
| CMOS DRAKE | All (with 9 pin connectors)) |
| ChoiceMMed | HCSMD400, MD300A, MD300I, MD300K1, MD300M, MMED6000DP-M3, MMED6000DP-M7, MMED6000DP-S6, MMED6000DP-SF |
| Digicare | Digimax 2000, Digimax 5500 |
| Draeger | Oxipac 2000, Oxipac 2500 |
| Envitec | PulsiQuant 8040 |
| Goldway | UT4000A |
| Infinium | Oxcyon II |
| Invacare | 3300nv |
| McKesson | Oximeter 16-834V2 |
| PaceTech | Monitors that have a 7-pin connector |
| RGB Medical Devices | Omicrom FT, Omicron PREMIUM |
| Skanray > Larsen and Toubro | Cosmic, Galaxy, Planet, Planet 50, Star 50, Star 55, Stellar P |
| Smiths Medical > BCI | 1300, 1301, 1302, 1303, 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3400, 3401, 3403, 3404, 3444, 4700, 6100, 9100, 9200, Advisor, Autocorr, Capnocheck 9004, Mini Torr, Mini Torr Plus, Spectro 10, Spectro 20, Spectro2 10, Spectro2 20, Spectro2 30, SurgiVet, Vet/Ox Plus 4600 |
| Spacelabs | PRO2 |
| Venni | VI-100A, VI-200A |
| Weinmann | Oxycount Mini |
Technical Specifications:
| Label | Value |
|---|---|
| Cable Color | Gray |
| Cable Diameter | 4 mm |
| Cable Material | TPU Jacket |
| Category | SpO2 |
| Certifications | FDA, CE, ISO 80601-2-61:2011, ISO10993-1, 5, 10:2003E, TUV, RoHS Compliant |
| Connector Distal | Male 9-Pin D-Sub Connector |
| Connector Proximal | Adult Clip |
| Latex-free | Yes |
| Packaging Type | Bag |
| Packaging Unit | 1 |
| Patient Size | Adult (>40Kg) |
| SpO2 Technology | BCI |
| Sterile | No |
| Total Cable Length | 3.5 ft |
| Warranty | 12 months |
| Weight | 0.4lb |
OEM part numbers for other variants
Adult Soft
| Manufacturer | Part Number |
|---|---|
| AMC | PR-A900-1001N |
| Envitec | R-3222-12, R-3222-12plus (Autoclavable) |
| Mediaid | CST100-3104 (3 ft), CST100-31049 (9 ft) |
| Sage | P13S-11MP |
| Cables and Sensors | S403S-060 |
Pediatric Clip
| Manufacturer | Part Number |
|---|---|
| AMC | PR-A120-1001N |
| Huntleigh | ACC-VSM-170 |
| Mediaid | CST062-3104 (3 ft), CST062-31049 (9 ft) |
| Smiths Medical > BCI | 3178 |
| Cables and Sensors | S103-060 |
Pediatric Soft
| Manufacturer | Part Number |
|---|---|
| Envitec | RM-3222-12, RM-3222-12plus (Autoclavable), RS-3222-12 (Infant), RS-3222-12plus (Infant autoclavable) |
| Mediaid | CST102-3104 (3 ft), CST102-31049 (9 ft) |
| Cables and Sensors | S103S-060 |
Infant soft (Small)
| Manufacturer | Part Number |
|---|---|
| Cables and Sensors | S203S-060 |
Neonate Soft
| Manufacturer | Part Number |
|---|---|
| ChoiceMMed | M-50C |
| Smiths Medical > BCI | 3025, 3026 |
| Cables and Sensors | S303-060 |
Adult Ear Clip
| Manufacturer | Part Number |
|---|---|
| AMC | PR-A220-1001N |
| Envitec | ES-3222-12 |
| Smiths Medical > BCI | 3078, WW3078, 20230-EP |
| Cables and Sensors | S903-060 |
Multi-Site
| Manufacturer | Part Number |
|---|---|
| AMC | PR-A320-1001N |
| Envitec | Y-2227 |
| Mediaid | CST070-3104 (3 ft), CST070-31049 (9 ft) |
| Smiths Medical > BCI | V1703, 3043 |
| Cables and Sensors | S803-060 |