Medtronic Microstream Compatible EtCO2 Intubated FilterLine Sampling Line MVAI / M1920A - Capnomed 5212S-10 - Box of 25

$189.00
TitleSelected: Default Title
Quantity
Rapid ShippingQuick Turnaround, Every Time.
Premium StandardISO 13485:2016 Certified Company.
Up to 50% SavingsHigh Quality. Low Cost.
OEM-Standard QualityBacked By Warranty.

Specifications

OEM Part Number Cross References:

ManufacturerPart Number
Medtronic > CovidienMVAI (legacy XS04620) (FilterLine Set, Adult/Pediatric, 25/box), MVAI100U (legacy 010579) (Same line, 100/box)
PhilipsM1920A (989803105531) (FilterLine Set, intubated, adult/pediatric), 989803204511 (Microstream Advance intubated line, adult/pediatric, 2 m (equivalent))

Compatibility:

ManufacturerModel
PhilipsMicrostream Extension M3015A, M3015B, IntelliVue MP5 (M8105A, M8105AS), VM8 (863066), VM1 (863266), Efficia CM10 (863301), CM12 (863303), CM100 (863300), CM120 (863302), CM150 (863304), HeartStart MRx M3535A/A06, M3536A/A06, M3536M, 862478, 863063, 863064, 863065, 863068, 863088 (product numbers per Capnomed/Philips)
Medtronic > CovidienMicrostream-enabled monitors and modules (any Microstream monitor per Capnomed)

Technical Specifications:

LabelValue
Capnomed Model5212S-10 (MemoLine 5212 series)
Product TypeIntubated EtCO2 sampling line (FilterLine Set-type)
CategoryEtCO2 Sampling Lines
TechnologyMicrostream-compatible
PatientAdult (Capnomed); OEM MVAI is rated adult/pediatric †
Use DurationShort-term (low humidity)
Tube Length2.5 m (8.2 ft) (OEM: 2.0 m)
O2 DeliveryNo
Device ConnectionMicrostream FilterLine connector
Patient ConnectionAirway adapter between ventilator Y-piece and endotracheal tube
ET Tube Size> 4.5 mm †
Product Weight (incl. packaging)20.4 g
LatexNot made with natural rubber latex
DEHP-FreeNot stated by Capnomed
SterileNon-sterile
UseSingle-patient use; replace per patient, max. 7 days (MemoLine IFU)
CE MarkedYes (per Capnomed)
Packaging25 per box
Warranty6 months

Product Details

Capnomed 5212S-10 is a compatible Microstream-type intubated FilterLine sampling line, equivalent to Medtronic MVAI (legacy XS04620) and Philips M1920A. It connects to Microstream-enabled capnography monitors and modules for dependable short-term EtCO2 monitoring.

† OEM reference value from the original manufacturer's documentation; not stated by Capnomed. Specifications are from Capnomed product documentation unless noted.

This is a compatible product manufactured by Capnomed. It is not made by or affiliated with the original equipment manufacturer; all brand names and part numbers are used for reference only. Please verify compatibility with your equipment before use.