OEM Part Number Cross References:
| Manufacturer | Part Number |
|---|---|
| Medtronic > Covidien | MVAN (legacy 008174) (Microstream Advance nasal line / Nasal NIV Line, adult) |
| Philips | M4686A (Microstream NIV Line, adult, 2 m), 989803204611 (Direct replacement for M4686A) |
Compatibility:
| Manufacturer | Model |
|---|---|
| Philips | IntelliVue, Efficia, VM and VS series with Microstream CO2 (per Capnomed), Microstream Extension M3015A, M3015B, IntelliVue MP5 (M8105A, M8105AS), VM8 (863066), VM1 (863266), Efficia CM10 (863301), CM12 (863303), CM100 (863300), CM120 (863302), CM150 (863304) |
| Medtronic > Covidien | Microstream-enabled monitors and modules (OEM MVAN application †) |
Technical Specifications:
| Label | Value |
|---|---|
| Capnomed Model | 5212S-30 (MemoLine 5212 series) |
| Product Type | Nasal CO2 sampling line |
| Category | EtCO2 Sampling Lines |
| Technology | Microstream-compatible |
| Patient | Adult, non-intubated |
| Use Duration | Short-term (low humidity) |
| Tube Length | 2.5 m (8.2 ft) (OEM: 2.0 m) |
| O2 Delivery | No |
| Device Connection | Microstream FilterLine connector |
| Patient Connection | Nasal prongs; over-the-ear tubing with chin slider |
| Product Weight (incl. packaging) | 18.0 g |
| Latex | Not made with natural rubber latex |
| DEHP-Free | Yes (per Capnomed) |
| MRI Compatible | Yes (per Capnomed) |
| Sterile | Non-sterile |
| Use | Single-patient use; replace per patient, max. 7 days (MemoLine IFU) |
| CE Marked | Yes (per Capnomed) |
| Packaging | 25 per box |
| Warranty | 6 months |
Product Details
Capnomed 5212S-30 is a compatible Microstream-type nasal CO2 sampling line for adult non-intubated patients, equivalent to Medtronic MVAN (legacy Nasal NIV Line 008174) and Philips M4686A. It connects to Microstream-enabled capnography monitors and modules for comfortable short-term EtCO2 monitoring.