Philips Respironics Compatible EtCO2/O2 Nasal Sampling Cannula with O2 Delivery M2750A / 3469ADU - Capnomed 5210S-50 - Box of 25
$279.00
Quantity
Rapid ShippingQuick Turnaround, Every Time.
Premium StandardISO 13485:2016 Certified Company.
Up to 50% SavingsHigh Quality. Low Cost.
OEM-Standard QualityBacked By Warranty.
Specifications
OEM Part Number Cross References:
| Manufacturer | Part Number |
|---|---|
| Philips | M2750A (989803144451) (Legacy OEM part), 989803206641 (Current direct replacement for M2750A) |
| Respironics | 3469ADU-00 (LoFlo CO2 w/O2 Cannula, Nasal, Adult) |
Compatibility:
| Manufacturer | Model |
|---|---|
| Philips | LoFlo Sidestream CO2 Sensor M2741A, Sidestream / Capnography Extension M3014A, IntelliVue MP5 (M8105A), IntelliVue MP2 (M8102A), IntelliVue Multi-Measurement Module X2 (M3002A), 860335 (per Capnomed spec sheet and Philips M2750A page) |
Technical Specifications:
| Label | Value |
|---|---|
| Capnomed Model | 5210S-50 (MemoLine 5210 series) |
| Product Type | Nasal CO2 sampling cannula with O2 delivery |
| Category | EtCO2 Sampling Lines |
| Technology | Sidestream, Philips Respironics LoFlo-compatible |
| Patient | Adult, non-intubated |
| Use Duration | Short-term (low humidity) |
| Tube Length | 2.5 m + 3.7 m (8.2 ft + 12.1 ft) |
| O2 Delivery | Yes |
| Device Connection | Philips Respironics LoFlo sidestream CO2 sensor (M2741A); O2 tubing to O2 source |
| Patient Connection | Nasal prongs; over-the-ear tubing with chin slider |
| Product Weight (incl. packaging) | 65.8 g |
| Latex | Not made with natural rubber latex |
| DEHP-Free | Not stated by Capnomed |
| Sterile | Non-sterile |
| Use | Single-patient use; replace per patient, max. 7 days (MemoLine IFU) |
| CE Marked | Yes (per Capnomed) |
| Packaging | 25 per box (OEM: 10 per box) |
| Warranty | 6 months |
Product Details
Capnomed 5210S-50 is a compatible adult nasal sampling cannula that samples CO2 while delivering supplemental oxygen, designed as a replacement for Philips M2750A / Respironics 3469ADU-00. It works with the Philips Respironics LoFlo sidestream CO2 sensor for short-term capnography in non-intubated patients.
† OEM reference value from the original manufacturer's documentation; not stated by Capnomed. Specifications are from Capnomed product documentation unless noted.
This is a compatible product manufactured by Capnomed. It is not made by or affiliated with the original equipment manufacturer; all brand names and part numbers are used for reference only. Please verify compatibility with your equipment before use.